Snorkel Fume Hood Design and Installation for the USA and Beyond

Fume Hoods

What an Exhaust Snorkel Does

Some lab emissions start at a single point: the vent of a gas chromatograph, the end of a length of tubing or a small heated process on the bench. An exhaust snorkel captures those fumes right where they form, before they spread into the room. PSA Laboratory Furniture designs, delivers, installs and certifies snorkel exhaust systems alongside our full range of fume hoods, giving labs targeted, cost-efficient local ventilation.

A snorkel fume hood is a compact, ducted capture device that removes exhaust and fumes from a specific source. Snorkels are smaller than other ventilation hoods and can be positioned flexibly, which lets users capture contaminants close to where they are generated. Because the exhaust is ducted out of the building, a snorkel removes fumes rather than recirculating them into the lab.

snorklehood-groupimage

How a Lab Snorkel Works

A lab snorkel combines three parts. An articulating arm with movable joints lets the user reposition the intake. A capture hood or cone at the end of the arm draws in fumes at the source. Ductwork then carries the contaminated air to the building exhaust system. Users can swing the arm into place for a procedure and move it aside when the bench is needed for other work.

All Fume Hood Types

AddAirFumeHood

Add Air Fume Hoods Designed to increase face velocity for enhanced safety, it provides an extra layer of protection.

Learn more
ventilation-for-material-testing-feautre-img01

Airfoil Bypass Fume Hood Fume Hoods Engineered for superior airflow and containment. It guarantees optimal safety and efficiency in the lab.

Learn more
Canopy

Canopy Fume Hoods Ideal for non-hazardous applications that deal with heat, moisture, and smells. It offers versatile ventilation for a variety of lab tasks.

Learn more
HP Hoods 4

Thin Wall Fume Hoods Space-saving design for tight laboratory spaces. Maximizes usable workspace in the lab while maintaining safety standards.

Learn more
Demonstration

Demonstration Fume Hoods Versatile hoods for teaching and display. Perfect for educational settings and public demonstrations.

Learn more
ventilation-for-material-testing-feautre-img02

High Performance Fume Hood Fume Hoods Designed to increase face velocity for enhanced safety, it provides an extra layer of protection

Learn more
LowBench1

Low Bench Fume Hoods Compact design for limited workspace environments. It maximizes efficiency and productivity in tight lab spaces.

Learn more
PArotatorimage

Perchloric Acid Fume Hoods Specialized for safe handling of perchloric acid. It assures proper containment and ventilation for hazardous substances.

Learn more
radioisotopes

Radioisotope Fume Hoods Meets safety standards for working with radioactive materials. Provides a secure environment for handling radioactive substances.

Learn more
Snorkel

Snorkel Exhaust Fume Hoods Effective exhaust system for spot ventilation. It is ideal for targeted ventilation of specific areas or equipment.

Learn more
fumerotatingimage

Variable Air Volume (VAV) Fume Hoods Energy-efficient with adjustable airflow capabilities. Adapts to changing lab conditions and reduces energy consumption.

Learn more
ventilation-for-material-testing-feautre-img03

Walk-In Fume Hoods Fume Hoods Large enclosures for extensive workspace requirements. It offers ample room for large-scale experiments and equipment.

Learn more

Lab Design Quote

Get a customized lab design quote with a detailed CAD drawing in 48 hours. Let us help you create a functional and efficient laboratory layout.

Lab Furniture What we offer Step Form Img Step Form Img
  • Step 1:
    Select Laboratory Furniture
  • Step 2:
    Upload Artwork/Plan
  • Step 3:
    Project Timeline
  • Step 4:
    Contact Information

Snorkel Fume Collection Applications

Snorkel fume collection suits emissions that are small, localized and predictable. Common applications include:

  • Exhaust from gas chromatographs, pipe nipples or the end of equipment tubing
  • Atomic absorption instruments and other analytical equipment with a vent point
  • Soldering and small benchtop processes that release fumes
  • Heat and odors from ovens, water baths and similar equipment
  • Teaching labs where students work at many separate stations
snorkel2

Snorkel Hood Mounting Options

Most snorkel hoods hang from the ceiling, which keeps the work surface clear and lets one arm serve a wide area. Wall-mounted and bench-mounted snorkels can suit rooms where ceiling space is limited or where an arm needs to stay close to a fixed instrument. Ceiling-hung snorkels pair especially well with school laboratories and flexible furniture systems, since benches can move beneath them while the exhaust stays in place.

Positioning for Effective Snorkel Hood Ventilation

Effective snorkel hood ventilation depends on placement. A snorkel's capture strength weakens quickly as the distance from the intake grows, so the hood should sit as close to the emission point as the work allows. Training staff to reposition the arm for each task is one of the simplest ways to keep a fume snorkel performing as designed.

Snorkels supplement chemical fume hoods; they do not replace them. Work involving hazardous chemicals, splashes or reactions that need a physical barrier and full enclosure belongs in a fume hood. A well-planned lab often uses both, assigning each task to the device that suits it.

Snorkel Hoods for Safe Labs in Any Industry

Snorkel fume hoods are critical to maintain regulatory compliance. Without a functioning fume hood, your lab can quickly fill with hazardous fumes. Protect your lab personnel with a fume hood from PSA Laboratory Furniture.

The better your fume hood’s performance, the safer your facility will be. We design and remodel laboratories all over the world for unparalleled safety and compliance with any industry standard.

snorkel2

Design, Installation and Certification From PSA

At PSA Laboratory Furniture, we have designed and built laboratories for more than 40 years, and we offer one of the most extensive selections of chemical fume hoods available. Our team handles delivery, installation and certification, and we provide ventilation testing and certification, including annual recertification for Midwest labs to ANSI, AIHA and ASSE standards. We can also supply eyewash stations, drench hose units and emergency showers to complete the lab's safety equipment.

We guarantee a response within 24 hours and provide an initial CAD drawing within 2 business days, so planning can start quickly.

Request a quote to plan snorkel exhaust that captures fumes at the source in your lab. Get in touch with us to learn more today.

Frequently Asked Questions About Snorkel Fume Hoods

A snorkel does not replace a fume hood. Snorkels capture small, localized emissions at a single point, while a chemical fume hood encloses the work and provides a sash barrier for hazardous chemicals and reactions. Labs that run both instrument work and wet chemistry typically benefit from having each device, matched to the tasks it handles best. A review of the procedures performed in each area can show where a snorkel is enough and where full containment is needed.

Service Areas

PSA Laboratory Furniture Works with Companies Across
the Country

PSA Laboratory Furniture provides laboratory furniture to companies across the United States. Our centralized geographic location allows efficient project coordination regardless of your company’s location. PSA’s goal is to respond to your laboratory's needs promptly nationwide.